 SELECT THE CORRECT ANSWER:

1)   Name of the meter used to measure Air velocity                                                          (c)

 

a.

b.

Multi meter

Anemometer

c.

d.

Thermometer

Ammeter

2)           Name the Electrolyte used in lead acid cells                                                           (a)

a.

b.

Sulpheric Acid

Hydrochloric Acid

c.

d.

Nitric acid

Phasphoric Acid

3)           Inverter converts                                                                                                     (a)

a.

DC to AC

c.

AC to AC

b.

DC to DC

d.

AC to DC

4)           Capacitor bank are used at substations to                                                             (c)

a.

b.

Avoid short-circuiting

Improve load factor

c.

d.

Improve P.F

Supply power in emergency

5)           Circuit breaker is                                                                                                  (a)

a.

b.

Current breaking device

Attention device

c.

d.

Amplifier

Starting device

6)           PSI is the unit of                                                                                                    (a)

a.

b.

Pressure

Temperature

c.

d.

Humidity

Velocity of gas

7)           Rectifier converts                                                                                                  (b)

a.

b.

DC to AC

AC to DC

c.

d.

AC to AC

DC to DC

8)           Maximum permissible value of Earth Resistance for a small sub-stn?                 (c)

a.

0.5 Ω

c

2.0 Ω

b

1.0 Ω

d

8.0 Ω

9)           Medium Voltage is clarified as                                                                              (d)

a

b

Less than 250V

650V to 33KV

c

d

Above 33KV

250V to 650V

10)         Single Phasing preventer is used to prevent?                                                     (c)

a

c

Single Phase voltage

Motors from single phasing

b

d

Three phase voltage

Motor to start

11)         What is the minimum safe value of insulation resistance for Motors?                 (a)

 

a

   c

10 M Ω

5 M Ω

b

d

15 M Ω

20 M Ω

(b)

12)              The dimensions of earth electrode?

a      3.0 mtr length x 40 mm dia  x   3.2mm thick                     b     2.5 mtrs length x 50mm dia x 3.2mm thick y                                                                                           

       c      3.0 mtrs length x 50mm dia x      3.2mm thick                   d     2.5mtrs length x 40mm dia x 3.2mm thick

13)         Earth Megger  used                                                                                          (      d     )

                 a      To measure insulation resistance of cables                      b     To measure voltage

c      To measure current                                                          d      To measure insulation resistance of earth

14)         Illumination levels measured by                                                                     (      a     )

a      Lux Meter                                          b      Hydrometer

c        Anemometer                                     c      Multimeter

A            Generation, Transmission & Distribution of Electrical Energy

15)          The integration time employed by supply authorities for recording M.D. for a 33 kV/415 V, 10 MVA Sub-station is –   (c)                       

a       5 minutes                                    b      15 minutes

C     45 minutes                                        d      60 minutes

16)         While designing a sub-station anticipated future loads in the next…. Years are taken:                (     d       )

a      1 year                                                b      2 years

c      20 years                                             d      5-7 years

17)         As per the present Tariff the minimum power factor of sub-station should be                        (     c      )

a      0.8                                                     b      0.85

c         0.98                                               d       0.95

18)         The 3 phase voltage unbalance in supply should not exceed                           (      a     )

a      2.5% to 5%                                         b      20%

c      25%                                                    d      10%

19)       For maintaining power supply quality the rate of change of frequency should not exceed     (c)

a

5Hz/Sec

b

10Hz/Sec

c

1 HZ/Sec

d

3    Hz/Sec.

 

 