RRB JOBS QUESTION BANK : JUNIOR ENGINEER (AC) FILL IN THE BLANKS

QUESTION BANK FOR SELECTION TO THE POST OF JUNIOR ENGINEER (AC)

FILL IN THE BLANKS:

1)         The process of removing heat from low temperature level and rejecting at high temperature is called.  REFRIGERATION.

2)          Any substances for change of its state at constant temperature absorbs/give up heat is called  LATENT HEAT.

3)         The  sum  of  sensible  heat  and  latent  heat  of  substance  in  process  is  called ENTHALPY.

4)         The latent heat of fusing ice is  144 BTU/LB.

5)         The unit of refrigeration is TON OF REFREGIRATION12000 Btu/Hr or 3023.98 K.Cal/Hr.

6)         The temperature measured by ordinary thermometer is called  SENSIBLE HEAT.

7)         What is the boiling point of water  100  C.

8)         AT what temperature water starts freezing_  0  C.

9)         One watt is  3.412 BTU.

10)       One BTU is  0.252 K.calaries.

11)       The unit of heat is  BTU OR K.CAL

12)       RMPU means  ROOF MOUNTED PACKAGE UNIT

13)       The setting of HP cutout in RMPU coaches is  415 psi.

14)       The setting of LP cutout in under slung coaches is  35 psi.

15)       The boiling point of refrigerant R22_  -40.8  C.

16)       The boiling point of refrigerant R12.  – 29.8  C.

17)       Artificial respiration is required to the person met with  electrical accident.

18)       R12 is being replaced with  R-134a in latest Refrigeration system.

19)       The latent heat of evaporation IS THE HEAT REQUIRED TO CHANGE THE LIQUID INTO VAPOUR.

20)       The temperature maintained in the refrigerator is LESS then  0  C.

21)       The dry bulb and vet bulb temperatures equals then the  RH is 100%

22)       The  moisture  absorption  in  refrigeration  circuit  is  done  by  DEHYDRATOR  CUM  FILTER.

23)       The commonly used refrigerants are  R 12 & R 22

24)       The lubrication of system in the sealed compressors is done by  FREEZOL

25)       The 3-phase voltage unbalance in supply should not exceed  2.5. % To 5%

26)       For maintaining power supply quality the rate of change of frequency should not exceed. 1 HZ/Sec.

27)       The voltage of 11 KV supply is  11000V

28)       Tender Notice is to be published for. Open tender

29)       Copper is the good conductor of electricity.

30)       Completion estimate is not  required for calling tender.

31)       Contingencies charges mean Transportation charges.

32)       Detailed estimate is to be prepared for  sanctioned works.

33)       Detailed estimate needs  sanction of HOD.

34)       The fire extinguisher used for Electrical fire is CO2

35)       Fire is the combination of  material and  temperature & Oxygen.

36)       B Type of fire extinguisher used to nullify the oil fires.

37)       Electric type of fire is clarified as  D type.

38)       CO2 type fire extinguisher is used for  electrical fires.

39)       Ordinary fire can be extinguished by  water.

40)       RUBBER HAND GLOVES are to be used while operating isolator handle in substations.

41)       Ordinary fire can be extinguished by  WATER OR SAND.

42)       Artificial respiration is required to the person met with  ELECTRICAL accident.

43)       Abbreviation for IOD is INJURED ON DUTY

44)       The accident causes with loss of human life is called  fatal accident.

45)       If a man touches a live wire, he gets  shock/electrocuted.

46)       CTC type extinguisher is used for  ELECTRICAL fire.

47)       If a transformer catches fire  FOAM type of fire.

48)       The fire extinguisher used for Electrical fire is CO2 TYPE.

49)       Fire is the combination of  Material, temperature and oxygen.

50)       B type of fire extinguisher used to nullify the oil fires.

51)       Electric type of fire is clarified as D type.

52)       CO2 type fire extinguisher is used for  ELECTRICAL fires.

53)       Soda ash type fire extinguisher is used for  GENERAL fires.

54)       CTC OR FOAM type of fire extinguishers will be used to extinguisher chemical fires.

55)       Axle Driven system working on 110 V DC supply.