RRB JOBS QUESTION BANK : CHIEF LOCO INSPECTOR - DIESEL LOCOMOTIVES - MULTIPLE CHOICE QUESTIONS
QUESTION BANK FOR SELECTION TO THE POST OF CHIEF
LOCO INSPECTOR -DIESEL (MECHANICAL DSL)
Diesel Locomotives - Multiple Choice Questions
1 What is the minimum Head light Focusing distance required in the locomotives provided with electrical head light? . d
a) 100 meters
b) 1000 meters
c) 2000 meters
d) 250 meters and above
2 What is the Fuel oil tank capacity in WDP1 locomotive in litres? c
a) 4000 b) 5000
c) 3000 c) 2000
3 When OPS drops or LLOB trips, the engine will_____ . b
a) Raise b) Shutdown
c) Comes to Idle d) Hunting
4 Expressor lube oil pump is driven by____. b
a) Gear
b) Chain
c) Motor
d) Belt
5 The exhaust manifold is connected to______part of the TSC. a
a) Gas Inlet Casing
b) Intermediate Casing
c) Turbine Casing
d) Blower Casing
6 One of the following is the equipment in Nose compartment .c
a) MR1
b) MR2
c) Control air pressure reservoir
d) All the above
7 How many Power Contactors are available in WDG4 Locomotive? .d
a) 7
b) 9
c) 8
d) 0
8 What is the Lube oil capacity(in litres) in WDP1 locomotives? a
a) 760
b) 910
c) 1100
d) 1457
9 If white smoke is emitting from exhaust chimney, what could be the reason? a
A) Water mixed with fuel
b) Governor oil mixed with fuel
c) Lube oil mixed with fuel
d) None of these oil
11 Water leaking continuously from water telltale pipe .b
a) Dummy it and work
b) Fail the loco further
c) Do fast pumping
d) Work on lower notches
12 Cooling Water capacity in WDM2 locomotive is liters..d
a) 900
b) 910
c) 1300
d) 1210
13 The rundown test of NAPIER Turbo is to be conducted on_______notch. a
a) Idle
b) 4
c) 6
d) 2
14 During one of the following occasions Hot engine alarm indication will get c
a) Continuous 8th notch working
b) Excess load
c) Water pump not working expansion tank
d) Full water in
15 The lube oil consumption for every 100 liters consumption of fuel on WDM2/WDG4 is b
a) 1.7/1.0 ltrs
b) 1.5/0.5 ltrs
c) 1.6/0.7 ltrs
d) 1.0/0.3 ltrs
16 ………………..type of speedometer is available on WDG4. b
a) Mechanical
b) Radar Sensor
c) Electrical
d) Electronic
17 The more Oxygenated Air is required for better_______ . b
a) Control air pressure
b) Combustion of fuel
c) Braking
d) Cooling
18 Hot engine alarm (HEA) will come at ______ degrees centigrade in WDG3A locos. c
a) 60
b) 70
c) 90
d) 80
19 Electro Pneumatic Governor is located in c
a) Expressor room
b) Radiator room
c) Nose compartment
d) Rear compartment
20 During the MR air pressure efficiency test ___kg /cm2 pressure should be created within minutes. d
a) 1.0 , 7
b) 1.5 , 6
c) 0.9 , 8
d) 0.7 , 5